{"id":12506,"date":"2007-11-10T10:58:54","date_gmt":"2007-11-10T09:58:54","guid":{"rendered":"http:\/\/elektrosystemy.pl\/?p=12506"},"modified":"2015-11-18T11:24:07","modified_gmt":"2015-11-18T10:24:07","slug":"ochrona-odgromowa-na-dachach-plaskich","status":"publish","type":"post","link":"https:\/\/elektrosystemy.pl\/?p=12506","title":{"rendered":"Ochrona odgromowa na dachach p\u0142askich"},"content":{"rendered":"<p><strong><a href=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/2015\/07\/09\/listopad-2007\/ES_2007_11.jpg\"><img loading=\"lazy\" class=\"alignleft wp-image-9600\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/2015\/07\/09\/listopad-2007\/ES_2007_11-209x300.jpg\" alt=\"ES_2007_11\" width=\"63\" height=\"90\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/2015\/07\/09\/listopad-2007\/ES_2007_11-209x300.jpg 209w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/2015\/07\/09\/listopad-2007\/ES_2007_11.jpg 600w\" sizes=\"(max-width: 63px) 100vw, 63px\" \/><\/a>Bezpo\u015brednie wy\u0142adowanie atmosferyczne w obiekt budowlany i towarzysz\u0105ce przep\u0142ywowi pr\u0105du piorunowego zjawiska termiczne i dynamiczne mog\u0105 wywo\u0142a\u0107 po\u017car lub spowodowa\u0107 znaczne szkody. Jako zabezpieczenie przed tego typu zdarzeniami stosowane s\u0105 r\u00f3\u017cnego typu, w zale\u017cno\u015bci od konstrukcji budynku, systemy odgromowe. Artyku\u0142 prezentuje rozwi\u0105zanie ochraniaj\u0105ce budynki z dachami p\u0142askimi opracowane przez firm\u0119 Dehn, we wsp\u00f3\u0142pracy ze specjalistami zrzeszonymi w ILPC (International Lightning Protection Club \u2013 Mi\u0119dzynarodowy Klub Ochrony Odgromowej).<\/strong><\/p>\n<p>Poprawnie zaprojektowana i kompleksowo wykonana ochrona odgromowa pozwala na minimalizacj\u0119 szkodliwych skutk\u00f3w wy\u0142adowania piorunowego. Nale\u017cy przy tym pami\u0119ta\u0107, \u017ce samo zainstalowanie systemu ochrony odgromowej zewn\u0119trznej nie eliminuje ca\u0142kowicie ryzyka, ale na pewno znacznie zmniejsza mo\u017cliwo\u015b\u0107 wyst\u0105pienia szk\u00f3d w obiekcie.<\/p>\n<div id=\"attachment_12507\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12507\" loading=\"lazy\" class=\"size-full wp-image-12507\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys1_DEHN.jpg\" alt=\"Rys. 1. Przyk\u0142ad instalacji odgromowej na dachu p\u0142askim\" width=\"600\" height=\"450\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys1_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys1_DEHN-300x225.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12507\" class=\"wp-caption-text\">Rys. 1. Przyk\u0142ad instalacji odgromowej na dachu p\u0142askim<\/p><\/div>\n<div id=\"attachment_12508\" style=\"width: 610px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys2_DEHN.jpg\"><img aria-describedby=\"caption-attachment-12508\" loading=\"lazy\" class=\"size-full wp-image-12508\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys2_DEHN.jpg\" alt=\"Rys. 2. Przyk\u0142ad instalacji odgromowej na dachu p\u0142askim\" width=\"600\" height=\"450\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys2_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys2_DEHN-300x225.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><p id=\"caption-attachment-12508\" class=\"wp-caption-text\">Rys. 2. Przyk\u0142ad instalacji odgromowej na dachu p\u0142askim<\/p><\/div>\n<p><strong>Dachy p\u0142askie<\/strong><\/p>\n<p>Obiekty z dachami p\u0142askimi s\u0105 zwykle eksponowane, tzn. z za\u0142o\u017cenia s\u0105 wystawione (nara\u017cone) na bezpo\u015brednie trafienia piorun\u00f3w. Przy braku zewn\u0119trznej instalacji odgromowej na takich powierzchniach mo\u017ce nast\u0105pi\u0107 uszkodzenie lub perforacja poszycia dachu w miejscu trafienia pioruna. Norma dotycz\u0105ca ochrony odgromowej obiekt\u00f3w budowlanych PN-IEC 61024-1: 2001 do ochrony p\u0142askich powierzchni zaleca bra\u0107 pod uwag\u0119 stworzenie sieci zwod\u00f3w os\u0142aniaj\u0105cej ca\u0142\u0105 powierzchni\u0119. Przyk\u0142adowe rozwi\u0105zania system\u00f3w ochrony odgromowej na dachach p\u0142askich pokazano na rysunku 1 i 2.<\/p>\n<div id=\"attachment_12509\" style=\"width: 494px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12509\" loading=\"lazy\" class=\"size-full wp-image-12509\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys3_DEHN.jpg\" alt=\"Rys. 3. Zastosowanie wspornik\u00f3w dachowych FB i FB2\" width=\"484\" height=\"405\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys3_DEHN.jpg 484w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys3_DEHN-300x251.jpg 300w\" sizes=\"(max-width: 484px) 100vw, 484px\" \/><p id=\"caption-attachment-12509\" class=\"wp-caption-text\">Rys. 3. Zastosowanie wspornik\u00f3w dachowych FB i FB2<\/p><\/div>\n<p><strong>Siatka zwod\u00f3w<\/strong><\/p>\n<p>Wymiary oka siatki zwod\u00f3w na dachu nie mog\u0105 by\u0107 wi\u0119ksze od warto\u015bci podanych w tablicy 1 normy PN-IEC 61024-1. Rozmiary uk\u0142adanej siatki s\u0105 zwykle uwarunkowane rozmiarami dachu i wyst\u0119powaniem na nim konstrukcji metalowych, wykorzystywanych jako naturalne elementy sieci zwod\u00f3w. Przy uk\u0142adaniu zwod\u00f3w na dachach z zieleni\u0105 w pod\u0142o\u017cu (i w granulacie) nie wolno stosowa\u0107 drutu aluminiowego.<br \/>\n<img loading=\"lazy\" class=\"alignnone wp-image-12510\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/Tab_1_dehn.jpg\" alt=\"Tab_1_dehn\" width=\"300\" height=\"303\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/Tab_1_dehn.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/Tab_1_dehn-100x100.jpg 100w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/Tab_1_dehn-297x300.jpg 297w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nNa rysunku 3 pokazano zastosowanie wspornik\u00f3w dachowych FB i FB2, przeznaczonych do swobodnego uk\u0142adania na zagospodarowanych dachach pokrytych zieleni\u0105, granulatem czy na dachach z betonu.<br \/>\nOdleg\u0142o\u015b\u0107 mi\u0119dzy wspornikami le\u017c\u0105cymi na dachu p\u0142askim powinna wynosi\u0107 oko\u0142o 1 m.<\/p>\n<div id=\"attachment_12511\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12511\" loading=\"lazy\" class=\"size-full wp-image-12511\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys4_DEHN.jpg\" alt=\"Rys. 4. Po\u0142\u0105czenie przewod\u00f3w z metalowym pokryciem attyki\" width=\"600\" height=\"441\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys4_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys4_DEHN-300x221.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12511\" class=\"wp-caption-text\">Rys. 4. Po\u0142\u0105czenie przewod\u00f3w z metalowym pokryciem attyki<\/p><\/div>\n<div id=\"attachment_12512\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12512\" loading=\"lazy\" class=\"size-full wp-image-12512\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys5_DEHN.jpg\" alt=\"Rys. 5. Zastosowanie mostk\u00f3w elastycznych (a, b, c) i sztywnych (d)\" width=\"600\" height=\"454\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys5_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys5_DEHN-300x227.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12512\" class=\"wp-caption-text\">Rys. 5. Zastosowanie mostk\u00f3w elastycznych (a, b, c) i sztywnych (d)<\/p><\/div>\n<p><strong>Wykorzystanie attyki<\/strong><\/p>\n<p>Je\u017celi attyka jest wykorzystywana jako naturalny element sieci zwod\u00f3w, to przewody u\u0142o\u017cone na wspornikach nale\u017cy po\u0142\u0105czy\u0107 z elementami attyki. Przyk\u0142ad takiego rozwi\u0105zania pokazano na rysunku 4.<br \/>\nJe\u017celi attyka spe\u0142nia rol\u0119 zwodu poziomego, nale\u017cy po\u0142\u0105czy\u0107 ze sob\u0105 jej pojedyncze odcinki, w celu zapewnienia ci\u0105g\u0142ej drogi dla przep\u0142ywu pr\u0105du piorunowego. Mo\u017cna do tego wykorzysta\u0107 mostki elastyczne (rys. 5a, b, c) lub mostki sztywne (rys. 5d). Mostki sztywne mog\u0105 znale\u017a\u0107 r\u00f3wnie\u017c inne zastosowanie. W przypadku bezpo\u015bredniego uderzenia pioruna w attyk\u0119 nale\u017cy liczy\u0107 si\u0119 z mo\u017cliwo\u015bci\u0105 wyst\u0105pienia perforacji (rys. 6). Je\u017celi ze wzgl\u0119d\u00f3w konstrukcyjnych obiektu sytuacja taka jest niedopuszczalna, zainstalowane na elementach attyki mostki sztywne mog\u0105 pe\u0142ni\u0107 dodatkowo rol\u0119 wspornik\u00f3w dla zwod\u00f3w pionowych (rys. 7a, b, c, d). Zgodnie z rysunkiem 7a, odleg\u0142o\u015b\u0107 pomi\u0119dzy zwodami wyznacza si\u0119 z metody tocz\u0105cej si\u0119 kuli (kula o promieniu odpowiednim dla skuteczno\u015bci ochrony), z za\u0142o\u017ceniem, \u017ce nie mo\u017ce zetkn\u0105\u0107 si\u0119 z powierzchni\u0105 chronionej attyki.<\/p>\n<div id=\"attachment_12513\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12513\" loading=\"lazy\" class=\"size-full wp-image-12513\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys6_DEHN.jpg\" alt=\"Rys. 6. Perforacja pokrycia attyki w wyniku uderzenia pioruna\" width=\"600\" height=\"568\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys6_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys6_DEHN-300x284.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12513\" class=\"wp-caption-text\">Rys. 6. Perforacja pokrycia attyki w wyniku uderzenia pioruna<\/p><\/div>\n<div id=\"attachment_12514\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12514\" loading=\"lazy\" class=\"size-full wp-image-12514\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys7_DEHN.jpg\" alt=\"Rys. 7. Mostki sztywne na pokryciu attyki jako wsporniki dla zwod\u00f3w pionowych\" width=\"600\" height=\"580\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys7_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys7_DEHN-300x290.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12514\" class=\"wp-caption-text\">Rys. 7. Mostki sztywne na pokryciu attyki jako wsporniki dla zwod\u00f3w pionowych<\/p><\/div>\n<p><strong>Unieruchomienie instalacji<\/strong><\/p>\n<p>Na dachach p\u0142askich, gdzie nie wyst\u0119puje pokrycie powierzchni kruszywem (granulatem), wsporniki instalacji odgromowej, o ile nie b\u0119d\u0105 przymocowane, mog\u0105 by\u0107 nara\u017cone na przemieszczenia spowodowane np. dzia\u0142aniem wiatru. W przypadku wspornik\u00f3w do zwod\u00f3w poziomych taka sytuacja nie powinna mie\u0107 miejsca, dlatego wymagane jest specjalne zabezpieczenie po\u0142o\u017cenia przewod\u00f3w stanowi\u0105cych uk\u0142ad zwod\u00f3w na dachu. W prezentowanym systemie znajduje si\u0119 specjalny wspornik dachowy KF \/ KF2 firmy Dehn \u2013 klejony do pokrycia dachowego. Przy czym na dachach pokrytych materia\u0142em bitumicznym tradycyjne wsporniki nie mog\u0105 by\u0107 na sta\u0142e przyklejone do dachu, poniewa\u017c wytrzyma\u0142o\u015b\u0107 po\u0142\u0105czenia klejonego jest zwykle niewystarczaj\u0105ca.<\/p>\n<div id=\"attachment_12515\" style=\"width: 487px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12515\" loading=\"lazy\" class=\"size-full wp-image-12515\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys8_DEHN.jpg\" alt=\"Rys. 8. Zastosowanie wspornik\u00f3w dachowych KF\" width=\"477\" height=\"373\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys8_DEHN.jpg 477w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys8_DEHN-300x235.jpg 300w\" sizes=\"(max-width: 477px) 100vw, 477px\" \/><p id=\"caption-attachment-12515\" class=\"wp-caption-text\">Rys. 8. Zastosowanie wspornik\u00f3w dachowych KF<\/p><\/div>\n<p><strong>Wsporniki KF<\/strong><\/p>\n<p>Mocowanie wspornik\u00f3w KF nale\u017cy wykonywa\u0107 przy pomocy pask\u00f3w (wed\u0142ug podanych na rysunku 8. wymiar\u00f3w \u2013 90 x 300 mm) z materia\u0142u zastosowanego pokrycia dachowego. Paskiem materia\u0142u przykleja si\u0119 do dachu doln\u0105 cz\u0119\u015b\u0107 wspornika po obu stronach. Wsporniki i klejone paski powinny tworzy\u0107 lini\u0119, a odleg\u0142o\u015bci pomi\u0119dzy wspornikami powinny wynosi\u0107 oko\u0142o 1 m. Paski materia\u0142u pokrycia dachowego powinny by\u0107 przyklejane wed\u0142ug zalece\u0144 producenta danego pokrycia dachowego (najcz\u0119\u015bciej przez podgrzanie gor\u0105cym powietrzem do temperatury oko\u0142o 500<sup>o<\/sup>C.) Dzi\u0119ki klejeniu zapobiega si\u0119 przesuwaniu przewodu ze wspornikiem na dachu p\u0142askim, a tym samym uszkodzeniom mechanicznym pokrycia. Wsporniki typ KF mog\u0105 by\u0107 stosowane na dachach o nachyleniu do 5<sup>o<\/sup>. Klejenie podk\u0142adek wspornika mo\u017cna wykona\u0107 przy pracach dekarskich prowadzonych przez wyznaczonych i przeszkolonych pracownik\u00f3w lub te\u017c przeprowadzi\u0107 samodzielnie.<\/p>\n<div id=\"attachment_12516\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12516\" loading=\"lazy\" class=\"size-full wp-image-12516\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys9_DEHN.jpg\" alt=\"Rys. 9. Nieprawid\u0142owa instalacja wspornik\u00f3w dachowych\" width=\"600\" height=\"480\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys9_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys9_DEHN-300x240.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12516\" class=\"wp-caption-text\">Rys. 9. Nieprawid\u0142owa instalacja wspornik\u00f3w dachowych<\/p><\/div>\n<div id=\"attachment_12517\" style=\"width: 610px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys10_DEHN.jpg\"><img aria-describedby=\"caption-attachment-12517\" loading=\"lazy\" class=\"size-full wp-image-12517\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys10_DEHN.jpg\" alt=\"Rys. 10. Zastosowanie element\u00f3w elastycznych do \u0142\u0105czenia przewod\u00f3w\" width=\"600\" height=\"450\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys10_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys10_DEHN-300x225.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><p id=\"caption-attachment-12517\" class=\"wp-caption-text\">Rys. 10. Zastosowanie element\u00f3w elastycznych do \u0142\u0105czenia przewod\u00f3w<\/p><\/div>\n<div id=\"attachment_12518\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-12518\" loading=\"lazy\" class=\"size-full wp-image-12518\" src=\"http:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys11_DEHN.jpg\" alt=\"Rys. 11. Kompleksowe rozwi\u0105zania ochrony odgromowej na dachach\" width=\"600\" height=\"400\" srcset=\"https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys11_DEHN.jpg 600w, https:\/\/elektrosystemy.pl\/wp-content\/uploads\/uncategorized\/2015\/11\/18\/ochrona-odgromowa-na-dachach-plaskich\/rys11_DEHN-300x200.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-12518\" class=\"wp-caption-text\">Rys. 11. Kompleksowe rozwi\u0105zania ochrony odgromowej na dachach<\/p><\/div>\n<p><strong>Kompensacja zmian temperatury<\/strong><\/p>\n<p>Elementy instalacji piorunochronnej na dachach obiekt\u00f3w nara\u017cone s\u0105 na dzia\u0142anie czynnik\u00f3w atmosferycznych (promieniowanie s\u0142oneczne, mr\u00f3z). Ma to szczeg\u00f3lne znaczenie w przypadku d\u0142ugich odcink\u00f3w zwod\u00f3w poziomych. Brak uwzgl\u0119dnienia oddzia\u0142ywania czynnik\u00f3w atmosferycznych na elementy instalacji mo\u017ce prowadzi\u0107 do deformacji siatki zwod\u00f3w oraz odrywania wspornik\u00f3w od pod\u0142o\u017ca (rys. 9).<br \/>\nZ uwagi na konieczno\u015b\u0107 kompensowania temperaturowych zmian d\u0142ugo\u015bci przewod\u00f3w, stosuje si\u0119 elementy elastyczne (rys. 10) w okre\u015blonych odleg\u0142o\u015bciach (tablica 2).<\/p>\n<p style=\"text-align: right;\"><strong>Krzysztof Wincencik<\/strong><br \/>\n<strong>Autor jest pracownikiem <\/strong><br \/>\n<strong>firmy Dehn Polska<\/strong><\/p>\n<p style=\"text-align: right;\"><strong>Andrzej Wincenciak<\/strong><br \/>\n<strong>Autor jest w\u0142a\u015bcicielem <\/strong><br \/>\n<strong>firmy FHU Wincenciak <\/strong><br \/>\n<strong>i cz\u0142onkiem ILPC<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Bezpo\u015brednie wy\u0142adowanie atmosferyczne w obiekt budowlany i towarzysz\u0105ce przep\u0142ywowi pr\u0105du piorunowego zjawiska termiczne i dynamiczne mog\u0105 wywo\u0142a\u0107 po\u017car lub spowodowa\u0107 znaczne szkody. Jako zabezpieczenie przed tego typu zdarzeniami stosowane s\u0105 r\u00f3\u017cnego typu, w zale\u017cno\u015bci od konstrukcji budynku, systemy odgromowe. Artyku\u0142 prezentuje rozwi\u0105zanie ochraniaj\u0105ce budynki z dachami p\u0142askimi opracowane przez firm\u0119 Dehn, we wsp\u00f3\u0142pracy ze specjalistami&hellip;<\/p>\n","protected":false},"author":3,"featured_media":12508,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[616],"tags":[440],"_links":{"self":[{"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/posts\/12506"}],"collection":[{"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=12506"}],"version-history":[{"count":1,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/posts\/12506\/revisions"}],"predecessor-version":[{"id":12519,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/posts\/12506\/revisions\/12519"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=\/wp\/v2\/media\/12508"}],"wp:attachment":[{"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=12506"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=12506"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/elektrosystemy.pl\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=12506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}